BRVAC™ Vacuum pumps & fittings
2026-11-26 · Reference

KF, ISO-K, ISO-F and CF: which flange system do you need

A working comparison of the four common vacuum flange systems, their standards, size ranges and the adapters required to join them.

Flange standards are not alternative brands of the same part. They are different sealing systems, and joining two of them always costs an adapter and usually limits the whole assembly to the weaker end.

The four systems

SystemSealingFasteningStandardTypical DN
KF / ISO-KFElastomer O-ring on a centering ringWing-nut clampISO 2861:2020 / DIN 2840310–50
ISO-KElastomer O-ring on a centering ringClaw clamps around the flangeISO 1609 / DIN 2840463–1000
ISO-FElastomer O-ring, boltedBolt circle through the flangeISO 1609 / DIN 2840463–1000
CF / ConFlatOFHC copper gasket against a knife edgeBolt circleISO 3669:201710–250+

The three rules that decide most questions

1. KF and ISO have no overlapping DN. KF ends at DN50; ISO starts at DN63. There is no KF63-to-ISO63 straight connection. A reducer or a dedicated adapter is mandatory, and its conductance becomes the bottleneck.

2. ISO-K and ISO-F share one dimension series. At the same DN the flange faces are dimensionally compatible; only the fastening differs. A coupling flange with claws on one side and a bolt circle on the other joins them. The DN must still match.

3. Mixing CF with an elastomer-sealed system limits the whole assembly. CF uses a metal knife edge and a copper gasket, baked to temperatures no elastomer tolerates. A CF-to-KF adapter exists, but the system's achievable vacuum and bake-out temperature are then set by the elastomer end, not the CF end.

KF dimensions worth memorising

DNFlange OD A (mm)Bore B (mm)ISO preferred
1030.012.2Yes
1630.017.2Yes
2040.017.0No
2540.026.2Yes
3255.034.0No
4055.041.2Yes
5075.052.3Yes

DN20 and DN32 are non-preferred sizes. Dimensions in published catalogues disagree for these two, so verify against the supplier drawing before machining a mating part.

Dimensions above are from public product catalogues citing ISO 2861:2020 / DIN 28403. They are reference values, not a substitute for the standard text or the supplier drawing.

Seal material sets the temperature ceiling

MaterialTypical service rangeReusable
NBR / Buna-N-20 to 100 °CYes
FKM / Viton-20 to 200 °CYes
FFKM / KalrezAsk the supplierYes
OFHC copper (CF)-200 to 450 °CNo

Published FKM bake-out limits vary between 150 °C and 200 °C. Use the conservative figure and confirm with the supplier datasheet. A copper gasket is single-use: a reused one is a leak.

Choosing by application

Note the distinction between leak rate and ultimate pressure: a typical elastomer-sealed KF joint is quoted around 1 × 10⁻⁹ mbar·L/s, while catalogues list vacuum ranges down to roughly 10⁻⁸ Torr for elastomer seals and 10⁻¹² Torr for metal gaskets. These are different measurements and are not interchangeable.

Model and inlet data compiled from LeyNow official product pages (leynow.com) and public flange standards. Unverified fields are marked as per factory datasheet.

Request a quote

All items are quote-on-request. Pick a model, tell us the quantity and where to reply; this page generates an email draft in your own mail client and stores nothing.

Static page, no backend: nothing is collected or stored.