BRVAC™ Vacuum pumps & fittings
2026-11-26 · Interface guide

G1/4, RC3/4, G1 1/4 vs KF25: matching fittings to pump inlets

The inlet connections used on LeyNow LP, LT/LX, LV, LD and WX pumps, and the adapters each one needs before a KF line can be built.

A vacuum pump is often ordered correctly and delivered with an inlet that cannot be connected to the rest of the system. The reason is that small pumps use two entirely different connection families, and the model number does not tell you which one.

Two connection families

Threaded ports appear on oil-free piston and oil-free rotary vane pumps, and on single-stage oil-lubricated rotary vane pumps. KF flanges appear on two-stage rotary vane and dry scroll pumps. A threaded port cannot accept a KF clamp, a centering ring or a KF elbow. It needs a thread-to-flange adapter first.

SeriesTypeInlet connectionWhat you need before a KF line
LP (e.g. LP-2000V)Oil-free silent pistonG1/4, inlet and outletG1/4 → KF16 or KF25 adapter
LT / LX (e.g. LX 0025 A01)Oil-free rotary vaneRC3/4RC3/4 → KF25 adapter
LV (e.g. LV 0063)Single-stage oil rotary vaneG1 1/4"G1 1/4" → KF40 adapter
LD (e.g. LD 0010)Two-stage oil rotary vaneKF25Centering ring, O-ring, clamp
WX (e.g. WX 0020H)Dry scrollKF25Centering ring, O-ring, clamp
Inlet data compiled from LeyNow public product pages. Series other than those listed are marked "per factory datasheet" in our catalogue rather than guessed.

Three thread standards that are not interchangeable

G (BSPP, parallel), RC (BSPT, tapered) and NPT look similar in a photograph and seal in different ways. G and RC share the same nominal diameter but use different thread forms; NPT uses a 60° thread angle against the 55° of BSP. An adapter cut for RC3/4 may thread into a G3/4 port but will not seal reliably.

When inquiring, quote the exact designation from the pump nameplate or datasheet — "RC3/4", not "3/4 inch". If the pump has a hose barb instead, give the barb outside diameter in millimetres.

Why the KF side also needs three parts

A single KF joint is not one part. It is a centering ring carrying an elastomer O-ring, a clamp that pulls two identical flange faces together, and the two flanges themselves. Ordering only a clamp is the most common incomplete bill of materials we see.

The flange faces are dimensionally defined by ISO 2861:2020 / DIN 28403. DN16, DN25 and DN40 are ISO preferred sizes; DN20 and DN32 exist in some catalogues with dimensions that vary between manufacturers, so they should be verified against the actual drawing.

DNFlange OD A (mm)Bore B (mm)ISO preferred
1630.017.2Yes
2540.026.2Yes
4055.041.2Yes
5075.052.3Yes

A checklist before you order

  1. Read the inlet designation from the pump datasheet, not from a reseller listing.
  2. Decide the KF nominal diameter for the line. KF25 is the practical default for small pumps; do not upsize without a conductance reason.
  3. If the pump is threaded, add one thread-to-KF adapter. If it is already KF, add a centering ring, an O-ring and a clamp per joint.
  4. Add one flexible bellows if the pump is hard-mounted and the line is rigid — vibration reaches the flange otherwise.
  5. Choose O-ring material from the actual temperature: NBR for general duty, FKM for higher bake-out. Ask the supplier for its datasheet rather than assuming a limit.
  6. For oil-lubricated pumps, specify an oil-mist exhaust filter separately. It is an outlet item, not an inlet fitting.

What we do not claim

This is a selection reference, not a stock list. Adapters and fittings are sourced per inquiry; lead time and material certificates are confirmed at quotation. No prices are published because the factory's terms and the shipping weight determine them per order.


Model and inlet data compiled from LeyNow official product pages (leynow.com) and public flange standards. Unverified fields are marked as per factory datasheet.

Request a quote

All items are quote-on-request. Pick a model, tell us the quantity and where to reply; this page generates an email draft in your own mail client and stores nothing.

Static page, no backend: nothing is collected or stored.