BRVAC™ Vacuum pumps & fittings
2026-11-26 · Selection guide

Oil-free vs oil-lubricated rotary vane pumps: choosing by duty

A practical comparison of oil-free and oil-lubricated vacuum pumps by contamination risk, ultimate pressure, maintenance and duty cycle.

The choice between an oil-free and an oil-lubricated pump is rarely about which one is "better". It is about what happens to the process gas, how often someone will service the pump, and what pressure the application actually needs.

The trade in one sentence

An oil-lubricated rotary vane pump uses oil as a sealant between vanes and stator. That gives it a low ultimate pressure and a forgiving tolerance to vapour, at the cost of oil mist at the exhaust, oil changes, and a theoretical backstreaming path into the chamber. An oil-free pump removes the oil from the gas path, at the cost of a higher ultimate pressure, tighter thermal limits and usually a higher purchase price for the same pumping speed.

Comparison by decision criterion

CriterionOil-lubricated rotary vaneOil-free (piston / scroll / screw / claw)
Contamination riskOil vapour can backstream; use a trap or filterNo oil in the gas path
Ultimate pressureLower, especially two-stage designsGenerally higher; check the datasheet
Water vapour / solvent loadTolerated with gas ballastCondensation inside the pump is a real risk
ExhaustOil mist filter needed in occupied spacesClean exhaust
Routine serviceOil and filter changesSeal / tip seal or element replacement
Noise and vibrationModeratePiston types can be louder at the same speed
Typical dutyPackaging, degassing, forming, lab backingMedical, analytical instruments, clean processes, load locks

Two mistakes that cost more than the pump

Specifying a lower ultimate pressure than the process needs. If a packaging line works at a few hundred Pa, a two-stage pump capable of high vacuum is wasted money and adds an oil-maintenance obligation. Start from the required working pressure, then add margin for line conductance, not from the best number in the catalogue.

Ignoring the vapour load. Drying, degassing and solvent processes put condensable vapour through the pump. On an oil-lubricated unit, vapour condenses into the oil and degrades it; a gas ballast and a defined oil-change interval are part of the specification, not an accessory. On a dry pump, the same vapour can condense inside the pumping chamber. Ask about the vapour tolerance before comparing nominal pumping speeds.

Where the LeyNow series sit

SeriesOil in gas pathTypical duty
LPNoMedical suction, lab instruments, pick-and-place
LT / LXNoVacuum handling, printing, packaging
LVYes, single-stagePackaging, degassing, forming
LDYes, two-stageAnalytical instruments, freeze drying, backing
WXNo, dry scrollClean processes, load locks, instruments
LS / LCNoChemical, pharmaceutical, central vacuum
LRDepends on backing pumpSpeed boost in the 1–100 Pa range
Series classification from the manufacturer's public product range. Exact ultimate pressure, pumping speed and oil charge are per model datasheet and are confirmed at quotation.

A short selection sequence

  1. Write down the required working pressure and the chamber or line volume.
  2. List condensable vapours and particulates in the process gas.
  3. Decide whether any oil backstreaming is acceptable. If not, go oil-free.
  4. Size the pump from pumping speed and conductance, not from motor power.
  5. Add the exhaust filter, inlet filter, anti-vibration feet and bellows as line items.
  6. Set the maintenance interval before the purchase order, not after the first failure.

The accessory question

Whichever family you choose, the first order should include the parts that keep it running: an inlet filter where dust is present, an exhaust mist filter for oil-lubricated units, anti-vibration feet, and the correct oil grade or seal kit. These are low-cost, high-repeat items, and specifying them together avoids a second freight charge on a small shipment.


Model and inlet data compiled from LeyNow official product pages (leynow.com) and public flange standards. Unverified fields are marked as per factory datasheet.

Request a quote

All items are quote-on-request. Pick a model, tell us the quantity and where to reply; this page generates an email draft in your own mail client and stores nothing.

Static page, no backend: nothing is collected or stored.